Dimensions Orifice Weld Neck RF flanges ASME B16.36 Class 2500

Weld Neck Orifice flange Raised Face type

OTHER PRESSURE CLASSES

300
600
900
2500
NPS DIA
RF
OUT
SIDE
DIA
MIN
THK
FLG
HGT
FLG
HUB
DIA
HUB
DIA
DIA OF
TAB
R O T H X A Tg
1 50.8 160 38.1 92 57 33.5 6.4
1.1/2 73.0 205 44.5 111 79 48.3 6.4
2 92.1 235 50.8 127 95 60.3 6.4
2.1/2 104.8 265 57.2 143 114 73.0 6.4
3 127.0 305 66.7 168 133 88.9 9.5
4 157.2 355 76.2 190 165 114.3 12.7
6 215.9 485 108.0 273 235 168.3 12.7
8 269.9 550 127.0 318 305 219.1 12.7
10 323.8 675 165.1 419 375 273.0 12.7
12 381.0 760 184.2 464 441 323.8 12.7

Weld Neck Orifice flange
NPS BOLT
CIRCLE
NO OF
BOLTS
DIA OF
HOLES
DIA
STUD
BOLTS
STUD
BOLT
LENGTH
1 108.0 4 1 7/8 150
1.1/2 146.0 4 1.1/4 1.1/8 180
2 171.4 8 1.1/8 1 185
2.1/2 196.8 8 1.1/4 1.1/8 205
3 228.6 8 1.3/8 1.1/4 230
4 273.0 8 1.5/8 1.1/2 260
6 368.3 8 2.1/8 2 350
8 438.2 12 2.1/8 2 385
10 539.8 12 2 5/8 2.1/2 490
12 619.1 12 2 7/8 2.3/4 540

General Notes..

  • Dimensions are in millimeters, except for bolts and bolt holes.
  • Height of Raised Face (RF) in CLASS 2500 is 7 mm.
  • All other dimensions are in accordance with ASME B16.5.
  • Ring joint flanges larger than NPS 3 will require angular meter taps.

Notes..

  • Other NPT sizes may be furnished if required.
  • Bolt lengths for raised face flanges include allowance for orifice and gasket thickness
    of 6 mm (0.25 in.) for NPS 1 to NPS 12. Bolt lengths for ring-type joint flanges include
    allowance of 15 mm (0.62 in.) for NPS 1 to NPS 3.
  • Bore (B) is to be specified by the purchaser.
  • The length of the Stud Bolt does not include the height of the chamfers (points).
  • The length of the Stud Bolts includes one Spiral Wound Gasket with a 4.5mm thick sealing element, which is compressed to 3mm while tightening the Raised Face flange connection.

Tolerances
Tolerances on all dimensions shall be as shown in ASME B16.5 except for those shown below.

Pressure Tap Location
Tolerance on location of center of pressure tap hole from flange face shall be..

  • ±0.5 mm (±0.02 in.) for flanges smaller than NPS 4
  • ±0.8 mm (±0.03 in.) for flanges NPS 4 and larger

Bore Diameter

  • Bore diameter tolerance (Welding Neck flanges only) is ±0.5% of nominal value.


Studs are measured parallel to the axis (L) from the first to the thread without the chamfers (points). S = free threads equals 1/3 time bolt dia

Measuring lengths of Stud Bolts

 

Hex bolts are measured from under the head to the top of de bolt


Measuring lengths of Hex bolts




Explore the World of Piping


© Werner Sölken 2008 -  
All rights reserved.
www.wermac.org uses Google Analytics

Privacy Policy

I must be old. I still believe in respect.